Filtration & Monitoring Solutions for hydraulic oil and lubricants

Off-Line Unit for varnish removal

The plant in Putte was established in 1929 and today has 46 injection moulding machines ranging in clamping force from 35 to 2,700 tonnes.

One ENGEL injection moulding machine is contaminated with Varnish. Previous filter actions resulted in clean oil but no elimination of the Varnish. Especially when the oil is <40°C varnish tends to clog valves, filters and other small passages.

The solution for Polytec was a RMF Off-Line Filterunit.

Before RMF Off-Line Unit
MPC dE: 83
ISO class: 21/18/12

Results after 4 month
Potential Varnish MPC dE: 14,4
ISO class: 16/14/11

IMG_0662

Más información

¿Quieres saber qué RMF Systems puede hacer por usted?

Si usted está interesado en nuestros productos o servicios, por favor, póngase en contacto con nosotros para obtener más información. 

Productos

© RMF Systems 2018